State of logical high: input is connected to ground (GND) of the controller. It allowed to connect either directly or through the resistance less than 300 ohms. | State of logical high: input is connected to ground (GND) of the controller. It allowed to connect either directly or through the resistance less than 300 ohms. | ||
Installed in slot MOD-1 or MOD-2 controller [[Special: MyLanguage / Wiren Board 5 | Wiren Board 5]]. | Installed in slot MOD-1 or MOD-2 controller [[Special:MyLanguage/Wiren Board 5| Wiren Board 5]]. | ||
Three channels. | Three channels. |
Версия 17:17, 14 января 2016
Extension Module, 3 digital inputs
The module for connection of sensors, counters to the outputs of the type "Dry contact" or "open collector".
State of logic low: input in air.
State of logical high: input is connected to ground (GND) of the controller. It allowed to connect either directly or through the resistance less than 300 ohms.
Installed in slot MOD-1 or MOD-2 controller Wiren Board 5.
Three channels.
Pinout:
Terminal | Function |
---|---|
O1 | Input 1 |
O2 | Input 2 |
O3 | Input 3 |
GPIO
When installed in first slot MOD-1
Input | GPIO |
---|---|
O1 | 85 |
O2 | 76 |
O3 | 91 |
When installed in second slot MOD-2
Input | GPIO |
---|---|
O1 | 22 |
O2 | 23 |
O3 | 83 |