WB-MSx Consumer IR Manual/en: различия между версиями

Новая страница: «At the physical level, the module is connected via RS-485 interface. Modbus RTU Protocol is used to control the devices. In Wiren Board devices, M…»
(Новая страница: «'''Warning!''' Numbers used Modbus registers have changed since firmware version '''3.2.0'''. The instructions stated the new numbers of registers. If you are usi…»)
(Новая страница: «At the physical level, the module is connected via RS-485 interface. Modbus RTU Protocol is used to control the devices. In Wiren Board devices, M…»)
Строка 28: Строка 28:
'''Warning!''' Numbers used Modbus registers have changed since firmware version '''3.2.0'''. The instructions stated the new numbers of registers. If you are using a device with older firmware, the general principle remains the same, but the numbers of the registers are shifted; as it is — see the [[#Map registers, flags, and inputs (Inputs and Coils)|Map registers, flags, and inputs (Coils and Inputs)]]. A full description of IR device registers can be found in this article under [[#Register map|Register map]].
'''Warning!''' Numbers used Modbus registers have changed since firmware version '''3.2.0'''. The instructions stated the new numbers of registers. If you are using a device with older firmware, the general principle remains the same, but the numbers of the registers are shifted; as it is — see the [[#Map registers, flags, and inputs (Inputs and Coils)|Map registers, flags, and inputs (Coils and Inputs)]]. A full description of IR device registers can be found in this article under [[#Register map|Register map]].


=== Обмен данными ===
At the physical level, the module is connected via [[RS-485/en| RS-485]] interface. Modbus RTU Protocol is used to control the devices. In Wiren Board devices, Modbus data is transmitted over RS-485 communication lines. See the [[Протокол Modbus/en|Modbus Protocol]] page for details. Modbus-address of the device is set at the factory and marked on the label. The address can be changed programmatically. Details refer to the [[#Modbus control| Modbus control]].
На физическом уровне модуль подключается через интерфейс [[RS-485]]. Для управления модулем используется протокол Modbus RTU. В устройствах Wirenboard данные Modbus передаются по линиям связи RS-485. Подробнее смотрите страницу [[Протокол Modbus]]. Modbus-адрес модуля задается на заводе и нанесен на наклейке на его боковой стороне. Адрес может быть изменен программно. Подробно смотрите в разделе [[#Управление_по_Modbus|Управление по Modbus]].


В устройствах с версией прошивки '''3.1.0''' и позднее также можно изменить настройки параметров обмена данными — смотрите [[#Карта_регистров|таблицу регистров Modbus]].
В устройствах с версией прошивки '''3.1.0''' и позднее также можно изменить настройки параметров обмена данными — смотрите [[#Карта_регистров|таблицу регистров Modbus]].
12 063

правки