Wiren Board 5: CAN-ISO Extension Module

Материал из Wiren Board
Это утверждённая версия страницы. Она же — наиболее свежая версия.
Другие языки:


Hardware

CAN extension module

The extension module uses MCP2551 physical layer interface. CAN interface signals are galvanically isolated from the controller.

Can be installed only to MOD2 extension slot.


The module contains a 150 Ohm terminator between the H and l lines. To enable it, you need to close the jumper on the top side of the Board.

Operation in UART-CAN mode

The WBE-I-CAN-ISO module operates in UART-CAN mode. The UART-CAN bus (also called sometimes simply CAN or RS-CAN) uses the physical can layer for the half-duplex serial port of the UART.

The UART-CAN bus is mainly used in metering devices such as Mercury energy meters.

In UART-CAN mode, the module can be installed in any expansion slot, so you can install two WBE-I-CAN-ISO modules

Pinout

CAN signals are wired to O1-O3 terminal blocks.

Pinouot:

Terminal Function
O1 CAN L
O2 CAN H
O3 CAN GND (Isolated GND)


Configuration

CAN extension module

Configuration is set in the web interface: Configs section => Hardware Modules Configuration.

For CAN mode: in Internal slot 2, select "WBE-I-CAN-ISO" and click Save.

For UART-CAN mode: make sure that the corresponding slot (Internal slot 1 or Internal slot 2) is set to "None".

The device is detected immediately, no reboot is required.

Operation

In CAN mode, it is defined as can1. About can on Linux, see CAN.

Module operates in UART-CAN mode identically to the RS-485 extension module, see description.

Compatibility table

Mode Controller Audit MOD1 MOD2
CAN Wiren Board 5 5.3, 5.6 - +
UART-CAN Wiren Board 5 5.3, 5.6 + +